• Welcome to the website of Shenzhen PinsuTechnology Co., Ltd.!
  • Welcome to the website of Shenzhen PinsuTechnology Co., Ltd.!
  • Welcome to the website of Shenzhen PinsuTechnology Co., Ltd.!

Service Hotline:+86-400-7788-990

News

What is the cause of the gear pump sticking and how to solve it?

The glue filling machine is measured by a metering pump. At present, there are three mainstream pump bodies, gear pump, screw pump, plunger pump.

For low viscosity liquid, gear pump metering is particularly accurate, better than screw pump, plunger pump. In addition, gear pump is the most simple maintenance of all pump bodies, so it is widely used. At present, most of the gluing machines use gear pump to measure curing agent. Because the curing agent on the one hand is very thin, on the other hand no impurities. For glue with low viscosity and good fluidity, but with a small amount of filler, it can also be measured by gear pump.

Working principle of gear pump: two gears of the same size are meshed and rotated in a close fitting shell. The inside of the shell is similar to "8" shape. Two gears are installed inside, and the outer diameter and both sides of the gear are closely matched with the shell. When the two teeth of the extruder are meshed, they are filled with material from the two teeth of the extruder.

When the filling machine is not used for a long time, the gear pump does not work, does not rotate, or there is abnormal noise when running?

On the one hand, it may be due to the glue, such as polyurethane glue. If it is not used for a long time, the curing agent reacts with water and crystallizes, so the pump body is stuck, so the pump can't rotate or there is abnormal noise. On the other hand, it may be that the glue has fillers. If it is not used for a long time, the glue remains on the gear pump to produce sedimentation and cause blockage.

In view of the above two cases, we can take apart the gear pump to clean up, the gear pump disassembly is very simple, loosen a few spiral can be completed. If the glue crystallizes and cannot be removed, remove the gear pump as a whole and soak it in the cleaning agent for 1-2 days before disassembly and cleaning. Tianna water is recommended as the cleaning agent. The degumming effect of Tianna water is better, and the foam is relatively clean.
Prev:What are the cleaning solutions commonly used in automatic double fluid gluing machine? Next: How to solve the bubble problem in the automatic double liquid glue filling machine?
qq

Service

qq

Service

qq

Service

Hotline

+86-0755-27552990